4749-110 | | EC Type Examination Certificate | |
| Certificate | KIWA 18ATEX0031 X | Issued on | 2019-01-09 | Marking | II 2G Ex ia IIC T6…T4 Gb
II 2D Ex ia IIIC T85°C Db | Hazardous area | Zone 1, 2
Zone 21, 22 | Ambient temperature range | -40 °C to +55 °C for T6 (Gas)
-40 °C to +70 °C for T5
-40 °C to +80 °C for T4
-40°C to +55°C (Dust) |
|
4749-111 | | IECEx | |
| Certificate | IECEx KIWA 18.0014X | Issued on | 2019-01-09 | Marking | Ex ia IIC T6...T4 Gb
Ex ia IIIC T85 °C Db |
|
4749-180 | | EC Type Examination Certificate | |
| Certificate | KIWA 19ATEX0038 X | Issued on | 2019-10-10 | Marking | II 2G Ex ia IIC T6…T4 Gb
II 2D Ex ia IIIC T85°C Db
II 2G Ex db IIC T6…T4 Gb
II 2D Ex tb IIIC T80°C Db | Hazardous area | Zone 1, 2
Zone 21, 22 | Ambient temperature range | Ex i:
-40 °C to +55 °C for T6 (Gas)
-40 °C to +70 °C for T5
-40 °C to +80 °C for T4
-40°C to +55°C (Dust)
Ex d:
-55 °C to +65 °C for T6
-55 °C to +80 °C for T5
-55 °C to +85 °C for T4
Ex tb:
-55 °C to +65 °C |
|
4749-181 | | IECEx | |
| Certificate | IECEx KIWA 19.0022X | Issued on | 2019-10-10 | Marking | Ex ia IIC T6…T4 Gb
Ex ia IIIC T85°C Db
or
Ex db IIC T6…T4 Gb
Ex tb IIIC T80°C Db | Ambient temperature range | Ex i:
-40 °C to +55 °C for T6 (Gas)
-40 °C to +70 °C for T5
-40 °C to +80 °C for T4
-40°C to +55°C (Dust)
Ex d:
-55 °C to +65 °C for T6
-55 °C to +80 °C for T5
-55 °C to +85 °C for T4
Ex tb:
-55 °C to +65 °C |
|
4749-210 | | EC Type Examination Certificate | |
| Certificate | On request | Issued on | 2018-11-11 | Marking | II 2G Ex db IIC T6…T4 Gb
II 2D Ex tb IIIC T80°C Db | Hazardous area | Zone 1, 2 | Ambient temperature range | Ex d:
-55 °C to +65 °C for T6
-55 °C to +80 °C for T5
-55 °C to +85 °C for T4
Ex tb:
-55 °C to +65 °C |
|
4749-211 | | IECEx | |
| Certificate | On request | Issued on | 2018-11-11 | Marking | Ex db IIC T6...T4 Gb
Ex tb lllC T80 °C Db | Ambient temperature range | Ex d:
-55 °C to +65 °C for T6
-55 °C to +80 °C for T5
-55 °C to +85 °C for T4
Ex tb:
-55 °C to +65 °C |
|