3967 |  | GOST (EAC) - Type test |  |
| Certificate | RU C-DE.EX01.B.00160/20 | Issued on | 2020-01-29 | Marking | 3967-113:
1Ex ia IIC T6...T4 Gb,
Ex ia IIIC T80 °C Db
3967-813:
2Ex nA IIC T6...T4 Gc X
2Ex ic IIC T6...T4 Gc
Ex tc IIIC T80 °C Dc | Hazardous area | Typ 3967-113:
Zone 1 und Zone 21
Zone 2 und Zone 22
Typ 3967-813:
Zone 2 und Zone 22 | Ambient temperature range | T4: -45°C...+80°C
T5: -45°C...+70°C
T6: -45°C...+60°C |
|
3967-1 |  | IECEx |  |
| Certificate | IECEx PTB 08.0036 | Issued on | 2022-08-23 | Marking | Ex ia IIC T6...T4 Gb and
Ex ia IIIC T80°C Db | Hazardous area | Zone 1, 21 | Ambient temperature range | T6:-45°C...+60°C
T5:-45°C...+70°C
T4:-45°C...+80°C |
|
|  | NEPSI |  |
| Certificate | GYJ18.1064 | Issued on | 2018-02-06 | Marking | Ex ia IIC T4~T6 Gb
Ex iaD 21 T80
| Ambient temperature range | T6: -45°C...+60°C
T5: -45°C...+70°C
T4: -45°C...+80°C
|
|
|  | NEPSI |  |
| Certificate | GYJ18.1064 | Issued on | 2018-02-06 | Marking | Ex ia IIC T4~T6 Gb
Ex iaD 21 T80 | Ambient temperature range | T6: -45°C...+60°C
T5: -45°C...+70°C
T4: -45°C...+80°C |
|
|  | CCC Ex |  |
| Certificate | 2020322307003490 | Issued on | 2020-12-11 | Marking | Ex ia IIC T4 ~ T6 Gb
Ex iaD21 T80 |
|
|  | CCC Ex |  |
| Certificate | 2021322307003632 | Issued on | 2021-01-08 | Marking | Ex ia IIC T4 ~ T6 Gb
Ex iaD21 T80
|
|
|  | EC Type Examination Certificate |  |
| Certificate | PTB 06 ATEX 2027 | Issued on | 2019-07-03 | Marking | II 2G Ex ia IIC T6 Gb
II 2D Ex ia IIIC T80°C Db | Ambient temperature range | T6:-45°C...+60°C
T5:-45°C...+70°C
T4:-45°C...+80°C |
|
|  | EC Type Examination Certificate |  |
| Certificate | PTB 06 ATEX 2027 | Issued on | 2019-07-03 | Marking | II 2G Ex ia IIC T6 Gb
II 2D Ex ia IIIC T80°C Db | Ambient temperature range | Siehe Erstzulassung |
|
|  | TR CMU 1055 |  |
| Certificate | On request | Issued on | 2021-08-25 |
|
3967-113 |  | GOST (EAC) - Type test |  |
| Certificate | RU C-DE.EX01.B.00160/20 | Issued on | 2020-01-29 | Marking | 3967-113:
1Ex ia IIC T6...T4 Gb,
Ex ia IIIC T80 °C Db
3967-813:
2Ex nA IIC T6...T4 Gc X
2Ex ic IIC T6...T4 Gc
Ex tc IIIC T80 °C Dc | Hazardous area | Typ 3967-113:
Zone 1 und Zone 21
Zone 2 und Zone 22
Typ 3967-813:
Zone 2 und Zone 22 | Ambient temperature range | T4: -45°C...+80°C
T5: -45°C...+70°C
T6: -45°C...+60°C |
|
3967-8 |  | IECEx |  |
| Certificate | IECEx PTB 08.0038X | Issued on | 2008-08-28 | Marking | Ex nA II T6
Ex nL IIC T6
Ex tD A22 IP65 T 80°C | Hazardous area | Zone 2, 22 | Ambient temperature range | T6:-45°C...+60°C
T5:-45°C...+70°C
T4:-45°C...+80°C |
|
|  | Statement of Conformity |  |
| Certificate | PTB 06 ATEX 2028 X | Issued on | 2008-01-09 | Marking | II 3G Ex nA II T6,
II 3G Ex ic IIC T6**
II 3D Ex tc IIIC T80°C IP65** | Ambient temperature range | T6:-45°C...+60°C
T5:-45°C...+70°C
T4:-45°C...+80°C |
|
|  | Statement of Conformity |  |
| Certificate | PTB 06 ATEX 2028 X | Issued on | 2008-01-09 | Marking | II 3G Ex nA II T6,
II 3G Ex ic IIC T6**
II 3D Ex tc IIIC T80°C IP65** | Ambient temperature range | T6:-45°C...+60°C
T5:-45°C...+70°C
T4:-45°C...+80°C |
|
|  | TR CMU 1055 |  |
| Certificate | On request | Issued on | 2021-08-25 |
|
3967-813 |  | GOST (EAC) - Type test |  |
| Certificate | RU C-DE.EX01.B.00160/20 | Issued on | 2020-01-29 | Marking | 3967-113:
1Ex ia IIC T6...T4 Gb,
Ex ia IIIC T80 °C Db
3967-813:
2Ex nA IIC T6...T4 Gc X
2Ex ic IIC T6...T4 Gc
Ex tc IIIC T80 °C Dc | Hazardous area | Typ 3967-113:
Zone 1 und Zone 21
Zone 2 und Zone 22
Typ 3967-813:
Zone 2 und Zone 22 | Ambient temperature range | T4: -45°C...+80°C
T5: -45°C...+70°C
T6: -45°C...+60°C |
|